361H series high hydrostatic pressure differential pressure transmitter

f2065a0d-67e1-4fa0-9ca8-fe1bee2fc543 (1)
f2065a0d-67e1-4fa0-9ca8-fe1bee2fc543 (1)
>
<
Product Models:
Retail price
0.0
Market price
0.0
Number of views:
1000
Product description

• Adopt MEMS monocrystal silicon high-precision pressure sensor
• With high response speed and stability
• Measurement accuracy 0.04-0.075%FS
• The max. range ratio can reach to 100:1
• Adopt double overload protection technology
• With strong overload capability, the unidirectional pressure can reach to 25MPa
• The max. static pressure can reach to 25MPa
• Provide standard HART bus communication mode
• Sophisticated self-diagnosis and telecommunication function
• Highlighted LCD with backlight
• Local display screen which can rotate by 360º
• Convenient local zero clearing function
• Convenient local zero point, extreme point setting and calibration function
• Convenient local current loop calibration function

 

Performance index
The overal performance is the composition error based on the reference accuracy,

ambient temperature effects and range static-pressure effects.
               
Accuracy index
±0.04-0.075%FS range 
  
Stability
≤±0.2%FS/5 years

 

Concrete performance index

(Zero-base range, reference conditions, silicone oil filling liquid, 316 stainless steel isolation diaphragm, 4~20mA

analog output, the digital fine-tuning value is equal to the set point value of range.)

Accuracy
(The reference accuracy includes hysteresis, linear, setting ability and repeatability, which are based on terminal.) 
     ±0.04-0.075% range
    If the range is less than X
    ±[0.015+0.05]%

       X value:

Influence of static pressure
±0.15%/10MPa

Influence of zero point
Can correct the zero position again or conduct pressure zero position transference according to the field installation position etc.

Damping time constant
The total damping time constant is equal to the sum of the damping time constants of amplifier unit and diaphragm capsule. The

damping time constant of amplifier unit is adjustable within the range of 0~100s.
Diaphragm capsule (silicone oil)      
Time constant (s) (The time constant can be set according to the actual situation of field and is recommended 1S)    

Influence of installation position
The changing of installation position, which is parallel to the surface of diaphragm, will not cause the effect of null shift. If the change

between the installation position and the surface of diaphragm do not exceed 90°, the null shift within 0.4KPa can be corrected by

zero setting without influencing the range.

Influence of power supply

 Less than ±0.005% range/v

 

Functional parameter

  The limit value of range and sensor

Table 1: Range of 361H transmitter and limit value of sensor

Zero point and range adjustment requirements

  ·The zero point and range can be adjusted arbitrarily within the range limit value indicated in Table 1.

·The range should be larger than or equal to the min. range indicated in Table 1.

 

Applications  

    Measurement of liquid, gas and steam

 

Output

Two-wire 4-20mA, linear output or square root output is selectable for users. Digital process variable overlays on the 4-20mA

signal, which can be applied to the host machines according with HART protocol.

 

Power supply

Need external power supply. While standard transmitter (4-20mA) has no load, work at 14.5-45V DC.

 Loop load limit

The max. loop resistance is decided by the voltage of external power supply, the relations are as follows:

Note: The supply voltage range of transmitter with backlight display is 14.5~45V

     The supply voltage range of intrinsic-safety series transmitter is 14.5~28V.

    The working voltage while HART communication should be larger than 17.5V.

Limit of static pressure and max. overpressure

Unidirectional overpressure 25MPa, the max. static pressure 25MPa (ordinary), 40MPa (the highest)

Fault mode

Output code

While discovering the faults of sensor or microprocessor by self diagnosis, the transmitter will output one high or low alarm signal

to prompt the users. The alarm output value is subject to the factory configuration mode of transmitter:

    Linear output: 3.8<I<20.8

C4: I=20.8mA  high fault

CN: I=3.8mA  low fault

 

Temperature limit
Environment
-20℃~+70℃ (ordinary)
-40℃~+85℃ (the highest)
Storage
-46℃~110℃
With header: -40℃~85℃  
Process
Larger than or equal to the atmosphere, please see the following table

Table 2: Process temperature limit of 361H transmitter 

 

Humidity limit

0-100% relative humidity

 

Starting time

Reach to the performance index within 2s after the transmitter is power up.

 

Mechanical performance index

Electrical interface

ANSI(American-Standrad) NPT1/2(F) internal thread  

ISO (Chinese standard) M20×1.5 internal thread 

 

Process interface

No process interface (NPT1/4 internal thread on the chamber flange)

With waist-shaped interface: NPT1/2 taper pipe internal thread

With T-shaped interface: M20×1.5 external thread and back welding connecting pipe (stainless steel)

With waist-shaped interface matching used with NPT1/2 pressure-leading transition head and back welding connecting pipe (stainless steel)

Process liquid-contacting piece

Process isolation diaphragm: 316 stainless steel, hastelloy C 

 

Drain/vent valve

316 stainless steel

 

Process flange and interface

Carbon steel cadmium plate, 316 stainless steel

 

Non-liquid-contacting piece  

Shell

Aluminium die casting IP65

Coating

Spraying plastics

Meter cap O-ring

Nitrile rubber

 

Wiring diagram of terminal side

 
Scan the QR code to read on your phone
We could not find any corresponding parameters, please add them to the properties table

Related Products

Smart differential pressure flowmeter is a smart flowmeter based on battery-powered low-power Internet of Things technology. It is mainly used for the detection of large-diameter water flow in urban water affairs and municipal pipe networks. It uploads collected water flow data and other information to the cloud server through a wireless remote
There are numerous municipal fire hydrants, scattered installations, destruction of fire hydrants, embezzlement of fire-fighting water, insufficient pressure of fire-fighting pipelines, and other problems. As a result,
WP304D temperature collector adopts MEMS temperature sensor chip to be encapsulated in a specific case. The temperature sensor and the conversion circuit are integrated to form a small special temperature sensor. Its appearance is small and exquisite, the measurement accuracy is high, the reliability is good, the power consumption is low,

Messages

Username used for comment:
Messages
Description:
验证码

CONTACT

Fujian WIDE PLUS Precision Instrument Co., Ltd.
National unified technical service telephone:
ADD:No.16, Xingye West Road, Mawei High-tech Zone,Fuzhou,Fujian China 350015

FOLLOW US

Copyright © Fujian WIDE PLUS Precision Instrument Co., Ltd. Powered by www.300.cn 闽ICP备05035149号-1