Search
Confirm
Cancel
Industrial automation
搜索
Search
Industrial Automation

WP-8000-EX series thermocouple isolated safety barrier

1a9d94be-15b8-4751-bb15-02ba28b501e5 (2)
1a9d94be-15b8-4751-bb15-02ba28b501e5 (2)
>
<
Product Models:
Retail price
0.0
Market price
0.0
Number of views:
1000
WP-8000-EX series thermocouple isolation safety barrier, receives thermocouple signals or other millivolt signals in hazardous areas on site, after isolation and linearization, it is converted into linearized DC signals and output to the control system or other in the safe area Unit combination meter. Intelligent thermocouple isolation safety barrier. The thermocouple type and measuring range can be configured and set.
Product description

WP-8000-EX series thermocouple isolation safety barrier, receives thermocouple signals or other millivolt signals in hazardous areas on site, after isolation and linearization, it is converted into linearized DC signals and output to the control system or other in the safe area Unit combination meter.


  Intelligent thermocouple isolation safety barrier. The thermocouple type and measuring range can be configured and set.


   This isolated safety barrier requires independent power supply, electromagnetic isolation between the power supply-input circuit-output circuit.

 

◆ Features

 

● Thermocouple temperature transmission and isolation output.

  ● Intelligent, can carry out on-site configuration settings. You can also select a fixed thermocouple type and temperature range input.

  ● Modular watch movement design, no need for zero and full scale adjustment, automatic dynamic calibration of zero point, automatic temperature drift compensation.

  ● With working power indicator.

  ● Intrinsically safe input circuit [Exia]IIC, input circuit overcurrent protection.

  ● Plug and unplug terminal blocks, DIN rail card installation.

 

● Power supply

Power connection: independent terminal 13-, 14+, can be plugged and unplugged

   Power supply voltage: (20~30) VDC

  Current consumption: at 24VDC, <30mA (one in and one out)
            <45mA (one input and two output)

   Power indicator: power on, LED light on: green

 

● Input circuit (Exia IIC dangerous area)

 Input thermocouple type: K, E, S, B, R, T, N, W, J and other types of thermocouples

   Optional input millivolt signal: (-5~60) mV; or specified millivolt voltage range

 

●Output circuit (safe area)

  Output current: (4~20) mA

   Allowable load during current output: 0~350Ω (4mA~20mA, 0~20mA output)

   Output voltage: (1~5)V

   Voltage output impedance: ≤500Ω

   ripple (Vp-p): <10mV


●Performance

  

Standard accuracy: ±0.5%FS, ±0.2%FS

   Temperature drift: ±0.015%/℃

   Response time: ≤1s (10→90)%

   Stable time: ≤5s

   Influence of power supply voltage fluctuation: ±0.1% (allowable voltage range)

   Influence of load resistance change: ±0.1%/250Ω

   Channel isolation: isolation between input-output-power supply

   Insulation resistance: ≥100MΩ/500VDC (AC)

   Isolation capacity: 2500VAC/1 minute 50Hz

   Maximum explosion-proof voltage: 250VAC

  Anti-electromagnetic compatibility: in line with IEC 61000 related anti-electromagnetic standards

 

●Environmental parameters

 Working temperature: (-20~+60)℃

  Storage temperature: (-40~+80)℃

  Environmental humidity: (5~+95)%RH (no condensation)

 

● Structure

  Clip-on type; modular watch core; ABS material case; plug-in terminal

   Machine weight: about 110g

 

● Safety and explosion-proof certification parameters

 

The whole machine meets the relevant requirements of GB3836.1-2000 and GB3836.4-2000 standards

  Explosion-proof grade mark: [Exia]IIC

  Safety certification parameters:

   Um: 250V Uo: 28V Io: 93mA

  Po: 0.65W Lo: 2.4 mH Co: 0.05μF
 

◆ Dimensions

 Dimensions: width × height × depth = 16 × 116 × 110 (mm)

 
Scan the QR code to read on your phone
We could not find any corresponding parameters, please add them to the properties table

Related Products

Smart differential pressure flowmeter is a smart flowmeter based on battery-powered low-power Internet of Things technology. It is mainly used for the detection of large-diameter water flow in urban water affairs and municipal pipe networks. It uploads collected water flow data and other information to the cloud server through a wireless remote
There are numerous municipal fire hydrants, scattered installations, destruction of fire hydrants, embezzlement of fire-fighting water, insufficient pressure of fire-fighting pipelines, and other problems. As a result,
WP304D temperature collector adopts MEMS temperature sensor chip to be encapsulated in a specific case. The temperature sensor and the conversion circuit are integrated to form a small special temperature sensor. Its appearance is small and exquisite, the measurement accuracy is high, the reliability is good, the power consumption is low,

Messages

Username used for comment:
Messages
Description:
验证码

CONTACT

Fujian WIDE PLUS Precision Instrument Co., Ltd.
National unified technical service telephone:
ADD:No.16, Xingye West Road, Mawei High-tech Zone,Fuzhou,Fujian China 350015

FOLLOW US

Copyright © Fujian WIDE PLUS Precision Instrument Co., Ltd. Powered by www.300.cn 闽ICP备05035149号-1